The maximum cable lengths for SAAX1000-002 at 15 V connected to a Worldsensing (formerly sensemetrics) Thread logger are given in the table below.


WARNING: SAAX connected to Thread loggers must be configured to run on Regular Power mode only.



 

SAAX M2
segments
RST EL380004 (22 AWG)
Max cable length m
Measurand SKUCABU18
Max cable length m
Measurand SKUCABK14
Max cable length m
10120012001200
20120012001200
3091212001200
4072312001200
5059612001200
6050412001200
7043410531200
803799191200
903348101200
1002967201200
1102656421200
1202375761200
1302135171200
1401924651192
1501734191073
160155377965
170139338867
180125303776
190111270693
20099240615
21087211542
22076185473
23066159408
24056135347
25046113289
2603791233
2702970179
2802150128
290133178
30051230