The maximum cable lengths for SAAX1000-002 at 15 V connected to a Worldsensing (formerly sensemetrics) Thread logger are given in the table below.
WARNING: SAAX connected to Thread loggers must be configured to run on Regular Power mode only.
SAAX M2 segments | RST EL380004 (22 AWG) Max cable length m | Measurand SKUCABU18 Max cable length m | Measurand SKUCABK14 Max cable length m |
10 | 1200 | 1200 | 1200 |
20 | 1200 | 1200 | 1200 |
30 | 912 | 1200 | 1200 |
40 | 723 | 1200 | 1200 |
50 | 596 | 1200 | 1200 |
60 | 504 | 1200 | 1200 |
70 | 434 | 1053 | 1200 |
80 | 379 | 919 | 1200 |
90 | 334 | 810 | 1200 |
100 | 296 | 720 | 1200 |
110 | 265 | 642 | 1200 |
120 | 237 | 576 | 1200 |
130 | 213 | 517 | 1200 |
140 | 192 | 465 | 1192 |
150 | 173 | 419 | 1073 |
160 | 155 | 377 | 965 |
170 | 139 | 338 | 867 |
180 | 125 | 303 | 776 |
190 | 111 | 270 | 693 |
200 | 99 | 240 | 615 |
210 | 87 | 211 | 542 |
220 | 76 | 185 | 473 |
230 | 66 | 159 | 408 |
240 | 56 | 135 | 347 |
250 | 46 | 113 | 289 |
260 | 37 | 91 | 233 |
270 | 29 | 70 | 179 |
280 | 21 | 50 | 128 |
290 | 13 | 31 | 78 |
300 | 5 | 12 | 30 |