The maximum cable lengths for SAA500-001 at 8.3 V are given in the table below. Use an approved splice kit to add any cable to an existing SAAV, and ensure you account for the cable that is already attached.


NOTE: RST Surge unit adds 1.6 ohm per conductor equivalent to 29m of 22AWG, 70m of 18AWG, 181m of 14AWG, reduce table cable length when using an RST surge unit.


DTSAADevNet Thin 22DTSAASKUCABU18DTSAASKUCABU14
SAAV500-001 mMax cable length mSAAV500-001 mMax cable length mSAAV500-001 mMax cable length m
1223212562121200
1620616500161200
2018520448201148
2416624404241034
281502836528936
321373233232849
361243630236773
401134027540704
441034425044641
48944822848585
52865220852532
56785618956484
60716017260439
64646415564398
68586814068358
72527212572321
76467611276286
8041809980253
8436848684222
8831887588191
9226926392162
9622965296134
1001710042100108