The maximum cable lengths for SAAX1000-002 at 8.3 V are given in the table below. Use an approved splice kit to add any cable to an existing SAAX, and ensure you account for the cable that is already attached.
NOTE: RST Surge unit adds 1.6 ohm per conductor equivalent to 29m of 22AWG, 70m of 18AWG, 181m of 14AWG, reduce table cable length when using an RST surge unit.
DTSAA | DevNet Thin 22 | DTSAA | SKUCABU18 | DTSAA | SKUCABK14 |
SAAX1000-002 m | Max cable length m | SAAX1000-002 m | Max cable length m | SAAX1000-002 m | Max cable length m |
12 | 278 | 12 | 676 | 12 | 1200 |
16 | 259 | 16 | 629 | 16 | 1200 |
20 | 242 | 20 | 587 | 20 | 1200 |
24 | 226 | 24 | 549 | 24 | 1200 |
28 | 212 | 28 | 514 | 28 | 1200 |
32 | 199 | 32 | 482 | 32 | 1200 |
36 | 187 | 36 | 453 | 36 | 1161 |
40 | 175 | 40 | 426 | 40 | 1091 |
44 | 165 | 44 | 401 | 44 | 1027 |
48 | 155 | 48 | 377 | 48 | 966 |
52 | 146 | 52 | 355 | 52 | 910 |
56 | 138 | 56 | 335 | 56 | 857 |
60 | 130 | 60 | 315 | 60 | 807 |
64 | 122 | 64 | 297 | 64 | 760 |
68 | 115 | 68 | 279 | 68 | 715 |
72 | 108 | 72 | 262 | 72 | 672 |
76 | 102 | 76 | 247 | 76 | 632 |
80 | 95 | 80 | 231 | 80 | 593 |
84 | 89 | 84 | 217 | 84 | 555 |
88 | 84 | 88 | 203 | 88 | 520 |
92 | 78 | 92 | 189 | 92 | 485 |
96 | 73 | 96 | 177 | 96 | 452 |
100 | 68 | 100 | 164 | 100 | 420 |
104 | 63 | 104 | 152 | 104 | 390 |
108 | 58 | 108 | 140 | 108 | 360 |
112 | 53 | 112 | 129 | 112 | 331 |
116 | 49 | 116 | 118 | 116 | 303 |
120 | 44 | 120 | 107 | 120 | 275 |
124 | 40 | 124 | 97 | 124 | 249 |
128 | 36 | 128 | 87 | 128 | 223 |
132 | 32 | 132 | 77 | 132 | 198 |
136 | 28 | 136 | 68 | 136 | 173 |
140 | 24 | 140 | 58 | 140 | 149 |
144 | 20 | 144 | 49 | 144 | 126 |
148 | 17 | 148 | 40 | 148 | 103 |
152 | 31 | 152 | 80 | ||
156 | 23 | 156 | 58 | ||
160 | 14 | 160 | 36 | ||
164 | 15 |