The maximum cable lengths for SAA500-001 at 16.5 V via a Measurand SAA232 or SAA232-5 interface are given in the table below. Use an approved splice kit to add any cable to an existing SAAV, and ensure you account for the cable that is already attached.
WARNING: SAAV connected to Campbell Scientific data loggers must be configured to run on Regular Power mode only.
SAAV500 segments | RST EL380004 (22 AWG) Max cable length m | Measurand SKUCABU18 Max cable length m | Measurand SKUCABU14 Max cable length m |
20 | 1200 | 1200 | 1200 |
40 | 752 | 1200 | 1200 |
60 | 538 | 1200 | 1200 |
80 | 418 | 1015 | 1200 |
100 | 342 | 831 | 1200 |
120 | 290 | 703 | 1200 |
140 | 251 | 609 | 1200 |
160 | 221 | 537 | 1200 |
180 | 189 | 458 | 1174 |
200 | 162 | 393 | 1006 |
220 | 139 | 336 | 862 |
240 | 118 | 287 | 736 |
260 | 100 | 244 | 625 |
280 | 84 | 205 | 524 |
300 | 70 | 169 | 433 |
320 | 56 | 136 | 350 |
340 | 44 | 106 | 272 |
360 | 32 | 78 | 200 |
380 | 21 | 52 | 132 |
400 | 11 | 27 | 68 |