The maximum cable lengths for SAAX1000-002 at 16.5 V via a Measurand SAA232 or SAA232-5 interface are given in the table below. Use an approved splice kit to add any cable to an existing SAAX, and ensure you account for the cable that is already attached.
WARNING: SAAV connected to Campbell Scientific data loggers must be configured to run on Regular Power mode only.
SAAX M2 segments | RST EL380004 (22 AWG) Max cable length m | Measurand SKUCABU18 Max cable length m | Measurand SKUCABK14 Max cable length m |
10 | 1200 | 1200 | 1200 |
20 | 1200 | 1200 | 1200 |
30 | 940 | 1200 | 1200 |
40 | 752 | 1200 | 1200 |
50 | 627 | 1200 | 1200 |
60 | 538 | 1200 | 1200 |
70 | 470 | 1142 | 1200 |
80 | 418 | 1015 | 1200 |
90 | 376 | 914 | 1200 |
100 | 342 | 831 | 1200 |
110 | 314 | 762 | 1200 |
120 | 290 | 703 | 1200 |
130 | 266 | 646 | 1200 |
140 | 241 | 586 | 1200 |
150 | 219 | 532 | 1200 |
160 | 199 | 483 | 1200 |
170 | 181 | 439 | 1124 |
180 | 164 | 398 | 1020 |
190 | 149 | 361 | 924 |
200 | 134 | 326 | 835 |
210 | 121 | 294 | 752 |
220 | 108 | 263 | 674 |
230 | 97 | 235 | 601 |
240 | 86 | 208 | 532 |
250 | 75 | 182 | 466 |
260 | 65 | 158 | 404 |
270 | 55 | 134 | 344 |
280 | 46 | 112 | 287 |
290 | 37 | 91 | 232 |
300 | 29 | 70 | 180 |