The maximum cable lengths for SAA500-001 at 15 V connected to a Worldsensing (formerly sensemetrics) Thread logger are given in the table below.
WARNING: SAAV connected to Thread loggers must be configured to run on Regular Power mode only.
SAAV500 segments | RST EL380004 (22 AWG) Max cable length m | SKUCABU18 Max cable length m | SKUCABU14 Max cable length m |
20 | 1200 | 1200 | 1200 |
40 | 729 | 1200 | 1200 |
60 | 513 | 1200 | 1200 |
80 | 390 | 947 | 1200 |
100 | 311 | 754 | 1200 |
120 | 254 | 617 | 1200 |
140 | 211 | 513 | 1200 |
160 | 177 | 431 | 1103 |
180 | 150 | 363 | 931 |
200 | 126 | 307 | 786 |
220 | 106 | 258 | 661 |
240 | 89 | 215 | 551 |
260 | 73 | 177 | 453 |
280 | 59 | 142 | 365 |
300 | 46 | 111 | 284 |
320 | 34 | 82 | 210 |
340 | 23 | 55 | 140 |
360 | 12 | 29 | 75 |
380 | 2 | 5 | 14 |