The maximum cable lengths for SAA500-001 at 15 V connected to a Worldsensing (formerly sensemetrics) Thread logger are given in the table below.
WARNING: SAAV connected to Thread loggers must be configured to run on Regular Power mode only.
| SAAV500 segments | RST EL380004 (22 AWG) Max cable length m | SKUCABU18 Max cable length m | SKUCABU14 Max cable length m |
| 20 | 1200 | 1200 | 1200 |
| 40 | 729 | 1200 | 1200 |
| 60 | 513 | 1200 | 1200 |
| 80 | 390 | 947 | 1200 |
| 100 | 311 | 754 | 1200 |
| 120 | 254 | 617 | 1200 |
| 140 | 211 | 513 | 1200 |
| 160 | 177 | 431 | 1103 |
| 180 | 150 | 363 | 931 |
| 200 | 126 | 307 | 786 |
| 220 | 106 | 258 | 661 |
| 240 | 89 | 215 | 551 |
| 260 | 73 | 177 | 453 |
| 280 | 59 | 142 | 365 |
| 300 | 46 | 111 | 284 |
| 320 | 34 | 82 | 210 |
| 340 | 23 | 55 | 140 |
| 360 | 12 | 29 | 75 |
| 380 | 2 | 5 | 14 |