This article provides the maximum supported cable lengths for SAAV500 operating at 15V.


Because ShapeArray power requirements vary by construction, the applicable cable length limits depend on the serial number. Please refer to the section corresponding to your ShapeArray serial number range.


WARNING: Use an approved splice kit to add any cable to an existing SAAV, and ensure you account for the cable that is already attached. SAAV connected to Thread loggers must be configured to run on Regular Power mode only.


ShapeArrays with Serial Numbers Greater than 700,000


The maximum cable lengths for ShapeArrays with serial numbers greater than 700,000 at 15 V are given in the table below.


SAAV500

Segments

RST EL380004 (22 AWG)

Max cable length m

SKUCABU18

Max cable length m

SKUCABK14

Max cable length m

20

1200

1200

1200

40

1200

1200

1200

60

1200

1200

1200

80

1200

1200

1200

100

1200

1200

1200

120

1200

1200

1200

140

1108

1200

1200

160

966

1200

1200

180

852

1200

1200

200

758

1200

1200

220

679

1200

1200

240

611

1200

1200

260

552

1200

1200

280

500

1200

1200

300

454

1147

1200

320

412

1042

1200

340

374

946

1200

360

340

859

1200

380

308

778

1200

400

278

704

1200

420

251

634

1200



ShapeArrays with Serial Numbers Between 200,000-700,000


The maximum cable lengths for ShapeArrays with serial numbers between 200,000- 700,000 at 15 V connected to a Worldsensing (formerly sensemetrics) Thread logger are given in the table below.


 

SAAV500
segments
RST EL380004 (22 AWG)
Max cable length m
SKUCABU18
Max cable length m
SKUCABU14
Max cable length m
20120012001200
4072912001200
6051312001200
803909471200
1003117541200
1202546171200
1402115131200
1601774311103
180150363931
200126307786
220106258661
24089215551
26073177453
28059142365
30046111284
3203482210
3402355140
360122975
3802514