The maximum cable lengths for SAAX1000-002 at 15 V connected to a Worldsensing (formerly sensemetrics) Thread logger are given in the table below.
WARNING: SAAX connected to Thread loggers must be configured to run on Regular Power mode only.
| SAAX M2 segments | RST EL380004 (22 AWG) Max cable length m | Measurand SKUCABU18 Max cable length m | Measurand SKUCABK14 Max cable length m |
| 10 | 1200 | 1200 | 1200 |
| 20 | 1200 | 1200 | 1200 |
| 30 | 912 | 1200 | 1200 |
| 40 | 723 | 1200 | 1200 |
| 50 | 596 | 1200 | 1200 |
| 60 | 504 | 1200 | 1200 |
| 70 | 434 | 1053 | 1200 |
| 80 | 379 | 919 | 1200 |
| 90 | 334 | 810 | 1200 |
| 100 | 296 | 720 | 1200 |
| 110 | 265 | 642 | 1200 |
| 120 | 237 | 576 | 1200 |
| 130 | 213 | 517 | 1200 |
| 140 | 192 | 465 | 1192 |
| 150 | 173 | 419 | 1073 |
| 160 | 155 | 377 | 965 |
| 170 | 139 | 338 | 867 |
| 180 | 125 | 303 | 776 |
| 190 | 111 | 270 | 693 |
| 200 | 99 | 240 | 615 |
| 210 | 87 | 211 | 542 |
| 220 | 76 | 185 | 473 |
| 230 | 66 | 159 | 408 |
| 240 | 56 | 135 | 347 |
| 250 | 46 | 113 | 289 |
| 260 | 37 | 91 | 233 |
| 270 | 29 | 70 | 179 |
| 280 | 21 | 50 | 128 |
| 290 | 13 | 31 | 78 |
| 300 | 5 | 12 | 30 |