Accessories

Step-by-step guides for various tasks using Measurand Accessories.

Maximum Cable Lengths for SAAV500-001 Connected to Campbell Scientific Logger
The maximum cable lengths for SAA500-001 at 16.5 V via a Measurand SAA232 or SAA232-5 interface are given in the table below. Use an approved splice kit to ...
Thu, 20 Jun, 2024 at 2:21 PM
Maximum Cable Lengths for SAAX1000-002 Connected to Campbell Scientific Logger
The maximum cable lengths for SAAX1000-002 at 16.5 V via a Measurand SAA232 or SAA232-5 interface are given in the table below. Use an approved splice kit t...
Thu, 20 Jun, 2024 at 2:23 PM
Maximum Cable Lengths for SAAV500-001 Connected to DTSAA
The maximum cable lengths for SAA500-001 at 8.3 V are given in the table below. Use an approved splice kit to add any cable to an existing SAAV, and ensure ...
Wed, 12 Jun, 2024 at 11:07 AM
Maximum Cable Lengths for SAAX1000-002 Connected to DTSAA
The maximum cable lengths for SAAX1000-002 at 8.3 V are given in the table below. Use an approved splice kit to add any cable to an existing SAAX, and ensur...
Wed, 12 Jun, 2024 at 11:07 AM
Maximum Cable Lengths for SAAV500-001 Connected to Ackcio Beam Logger
The maximum cable lengths for SAA500-001 at 12.0 V are given in the table below. Use an approved splice kit to add any cable to an existing SAAV, and ensure...
Thu, 20 Jun, 2024 at 2:07 PM
Maximum Cable Length for SAAX1000-002 Connected to Ackcio Beam Logger
The maximum cable lengths for SAAX1000-002 at 12.0 V are given in the table below. Use an approved splice kit to add any cable to an existing SAAX, and ensu...
Thu, 20 Jun, 2024 at 2:12 PM
Maximum Cable Lengths for SAAV500-001 Connected to Worldsensing LS-G6-DIG-2 Logger
The maximum cable lengths for SAA500-001 at 12.0 V are given in the table below. Use an approved splice kit to add any cable to an existing SAAV, and ensure...
Thu, 20 Jun, 2024 at 2:32 PM
Maximum Cable Lengths for SAAX1000-002 Connected to Worldsensing LS-G6-DIG-2 Logger
The maximum cable lengths for SAAX1000-002 at 12.0 V are given in the table below. Use an approved splice kit to add any cable to an existing SAAV, and ensu...
Thu, 20 Jun, 2024 at 2:38 PM
Maximum Cable Lengths for SAAV500-001 Connected to Worldsensing Thread Logger
The maximum cable lengths for SAA500-001 at 15 V connected to a Worldsensing (formerly sensemetrics) Thread logger are given in the table below. WARNING...
Wed, 26 Jun, 2024 at 10:36 AM
Maximum Cable Lengths for SAAX1000-002 Connected to Worldsensing Thread Logger
The maximum cable lengths for SAAX1000-002 at 15 V connected to a Worldsensing (formerly sensemetrics) Thread logger are given in the table below. WARNI...
Wed, 26 Jun, 2024 at 10:34 AM